TEKTRONIX TAS 475 CALIBRATION and TEKTRONIX TAS 475 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX TAS 475 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX TAS 475 (TAS475)   Description / Specification:    
TEKTRONIX TAS 475 4 Ch 100 MHz Analog Oscilloscope

100 MHz Analog Oscilloscope. Four channel. Rise Time: <= 3.5 ns. Defection Factor: 2 mV/div to 5 V/div, continuously variable between V/div settings. Deflection Factor DC Accuracy: ±2.5%. Bandwidth Limit: 20 MHz, independent channel control. Input Coupling: AC, DC, GND. Max Input Voltage: 400 V (DC + peak AC) derate at 20 dB/decade from 100 KHz to 13 V at 3 MHz. Input R and C: 1 M-Ohm ±1% in parallel with 20 pF ±2.0 pF. Channel Isolation: >= 50 dB at 10 MHz, >= 35 dB at 100 MHz. Vertical Control: CH1; CH2; CH3; CH4; ADD CH1 +CH2; ADD CH3+CH4; INVERT any/all channels; ALTernate or CHOP between all channels. Common Mode Rejection Ratio: >= 10:1 at 50 MHz. Main Sweep Time Base Range: 0.5 s/div to 20 ns/div (to 2 ns/div with X10 magnification). Delayed Sweep Time Base Range: 5 ms/div to 20 ns/div (to 2 ns/div with X10 magnification). Time Base Accuracy: ±2%, ±3% magnified. Delay Jitter: 25000 to 1 for sweep speeds slower than 1 ms/div. 10,000 for all other sweep speeds. Triggering Main Mode Selections: AUTO LEVEL, (with auto baseline), AUTO, NORM, TV LINE, TV FIELD (both, odd and even), SGL, SEQ. Trigger Coupling: DC, HF Reject, Noise Reject, LF Reject and AC for both Main and Delayed. Trigger Sensitivity - DC: 0.30 division from DC to 25 MHz, increasing linearly to 1 div at 150 MHz.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX TAS 475. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your TEKTRONIX TAS 475 CALIBRATION and/or TEKTRONIX TAS 475 4 Ch 100 MHz Analog Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: